Row of teal cast-iron motors on a steel rack, drive-end shafts toward the aisle

Pole-change or converter · YD · YDT · YVF2

Variable speed electric motors

There are two ways JWMotor varies the speed of a three-phase motor. Change the number of poles, and the motor steps between two or three fixed speeds on contactors. Or change the frequency with a converter, and the speed moves through a band from 5 Hz to 100 Hz. This page compares the two.

2 or 3Fixed speeds, pole-change
ContactorsNo converter for YD and YDT
5–100 HzSpeed band, YVF2
IC416Separate fan on YVF2

Steps or a band

Speed of an induction motor is set by the supply frequency and the number of poles. Pole-changing motors change the poles. Variable frequency motors change the frequency.

YDYDTYVF2
How speed changesStator connection changes the polesStator connection changes the polesConverter changes the frequency
Speeds2 fixed speeds in the catalog (4/2, 6/4, 8/4). 3-speed versions on the series page2 or 3 fixed speedsAny speed in the band
Control gearContactorsContactorsFrequency converter
Torque curveStiff speed: rpm stays nearly constant as load changesVariable torque: torque follows the square of speedConstant torque 5–50 Hz, constant power above 50 Hz
Catalog range0.45–82 kW, frames 80–280Pairs 2/4, 4/6, 4/8, 6/8 and 4/6/80.18–375 kW, frames 80–355
Best forMachine tools, mixers, conveyors, winchesCentrifugal fans and pumpsConveyors, hoisting, cutting, winding, CNC

Catalog performance is at 380 V, 50 Hz. YD generates no high-frequency harmonics, which is why its series page also names laboratory equipment and auxiliary drives on precision machine tools.

Two blue motors of the same frame side by side, one with a standard fan cowl and one with a separate cooling unit at the rear

What each method gives you

At 50 Hz the synchronous speed is 3000 r/min with 2 poles, 1500 with 4, 1000 with 6 and 750 with 8. A pole-changing motor jumps between two or three of these. A converter moves anywhere between.

01

Pole change

Each speed has its own rating. A YD132M-4/2 gives 6.5 kW at 1450 r/min and 8 kW at 2880 r/min. No converter, shielded cable or filter in the circuit.

02

Frequency

Torque is held from 5 Hz to 50 Hz and power above 50 Hz. A YVF2-225M-4 gives 45 kW at 1480 r/min with 291 N·m, and holds that torque down to 5 Hz.

Choose by the duty

Start with how many speeds the machine really needs, and whether the load is a fan or pump.

Two fixed speeds, steady under load

Drill presses, milling machines, mixers and conveyors. Choose YD. See two speed motors.

A band of speeds, or long hours slow

Conveyors, extruders and lines that run below 50 Hz all day. Choose YVF2. See VFD motors.

Above base speed

Cutting and winding that run past 50 Hz at constant power. Choose YVF2 and check the top frequency in variable frequency motors.

A gear reducer lowers the output speed by a fixed ratio. It does not make the speed variable. For a motor that goes straight into an R, F, K or S reducer, see R/F/K/S series motors.

Pole-changing on contactors

When two or three speeds are enough, a pole-changing motor keeps the circuit simple.

Blue three-phase motor with a V-belt pulley on a slide base, contactor panel on the wall behind

Pole-changing · three-phase

YD and YDT Multi Speed Motors

The stator winding, typically a Dahlander connection, is switched by contactors. After the change the speed stays locked to the supply frequency at the new pole count. YD keeps a stiff speed for machines. YDT follows the fan and pump curve.

2 or 3 fixed speeds · contactor control · copper and silicon steel

Where each one goes

Machines

YD on machine tools, mixers and conveyors, and on winches and drilling machines in marine and mining work.

Air and water

YDT on cooling towers, ventilation, HVAC and pump stations.

Lines and process

YVF2 on conveyors, hoisting, extruders, textiles, metallurgy and CNC.

Industry pages: HVAC and ventilation · Water and wastewater · Material handling

Send the speeds you need

Tell us the speeds, not only the kilowatts. That decides pole-change or converter.

  • Each speed the machine runs at, or the frequency range
  • Kilowatts at each speed, or the old nameplate
  • Load: machine, fan, pump or conveyor
  • Supply voltage and frequency
  • Control you already have: contactors or a converter
  • Mounting: B3, B5, B35 or V1. The factory also builds B14, B34, V3 and V5.
Request a quote

Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected]

Before the quote

What is a variable speed electric motor?

A motor whose speed can be changed in service. JWMotor offers two kinds: pole-changing motors (YD and YDT) with two or three fixed speeds, and variable frequency motors (YVF2) that run through a speed band on a converter.

Is a pole-changing motor cheaper to run than a VFD?

It needs only contactors, with no converter, shielded cable or filter. On fans and pumps, YDT puts the saving at about 30–50% against a single-speed motor on mechanical throttling. A converter gives finer control, if the duty needs more than two or three speeds.

Can a pole-changing motor run on a converter?

YD and YDT are made for contactor switching. For converter duty, choose YVF2, which has the separate IC416 fan and reinforced insulation with VPI.

Which one holds speed best under load?

YD has a stiff speed-torque curve, so rpm stays nearly constant as the load changes. That is why its series page names drill presses and milling machines.

How low can YVF2 run?

Constant torque from 5 Hz. The separately powered fan keeps the motor cool at low speed, and S1 continuous duty at low speed is stated for conveyors, extruders and automated lines.