Motor in a ventilation room with a closed fan cowl and the shaft on the drive end

Variable torque · fans and pumps

YDT series motors

Multi-speed motors whose torque follows the square of the speed. Built for centrifugal fans and pumps. 0.45–82 kW, frames 80–280, 220–690 V.

0.45–82 kWPower
2 or 3Fixed speeds
80–280IEC frame
220–690 VRated voltage
Motor coupled to a centrifugal fan

Torque follows the fan curve

Both YD and YDT are multi-speed. On YDT the power output changes with the square of the speed, which is the curve of centrifugal fans and pumps.

SpeedsPole pairs
22/4, 4/6, 4/8
32/4/6, 4/6/8

The same pairs are published for YD. The winding design is what separates the two series.

What changes with speed

01

Square of speed

Output torque varies with the square of the speed. A constant-torque motor at the low speed is the case the series page calls excess power, over-excitation and overheating.

02

Affinity laws

The series page states that cutting speed by half drops power to about one eighth. Switching to the low speed in off-peak hours is the saving, without a frequency converter.

03

Against throttling

Compared with a single-speed motor held back by mechanical throttling, the series page puts the reduction at about 30–50% when the speed follows demand.

04

High inertia

Copper windings and a reinforced rotor are specified for the inertia of large fan impellers and water pumps, so the start stays smooth on belts, pulleys and couplings.

Duties named on the series page

Fans

Centrifugal fans, cooling towers and ventilation. Flow is changed by the contactor, not by a damper.

Pumps

Pump stations and water pumps, on the same variable-torque curve.

HVAC

High speed at peak hours, low speed off peak. Altitude up to 1,000 m. Above that altitude the series page calls for a power derating. Voltage tolerance is ±5%. Class H insulation is available.

Send the fan or the pump

Send the pole pair and the kilowatts at each speed, plus the duty.

  • Fan, pump, cooling tower or other duty
  • Pole pair and kilowatts at each speed
  • Voltage and frequency
  • IEC frame
  • Mounting: B3, B5, B35 or V1. The factory also builds B14, B34, V3 and V5.
Request a quote

Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected]

Before the quote

How is YDT different from YD?

Both are multi-speed. YDT is the variable-torque winding. Power follows the square of the speed so it matches centrifugal fans and pumps.

What saving does the series page state?

About 30–50% against a single-speed motor controlled by mechanical throttling, by using the high speed at peak and the low speed off peak. Halving speed is stated to drop power to about one eighth.

Will it start a large fan?

The series page specifies copper windings and a reinforced rotor for the inertia of large industrial fans and water pumps.