YD · YDT · 2 or 3 speeds
Multi speed motors
Two series, both changed by pole count. Contactors select 2 or 3 fixed speeds. YD holds a stiff speed. YDT follows the fan and pump curve. 0.45–82 kW, frames 80–280.
The speed is the pole pair
YD and YDT publish the same pairs. A two-speed motor is one of the first row. A three-speed motor is one of the second. Each speed has its own kilowatts.
| Speeds | Pole pairs | How the series page describes the step |
|---|---|---|
| 2 | 2/4, 4/6, 4/8 | One winding connection for the high speed, one for the low speed |
| 3 | 2/4/6, 4/6/8 | Three connections, three fixed speeds |
The worked example on the YD page is 4 poles to 8 poles, 1500 rpm and 750 rpm. That is one 4/8 step, not the speed of every pair. Altitude on both series pages is up to 1,000 m, with a power derating above that. Voltage tolerance is ±5%. Class H insulation is available.
Contactors change the winding
Speed comes from the stator connection, typically a Dahlander winding. The contactors select the connection. After the change, speed stays locked to the supply frequency at the new pole count.
01
Copper and silicon steel
The YD page describes the motor for dust and heavy vibration, and for sites where the circuit is contactors rather than a converter stack.
02
No high-frequency harmonics
YD generates none, which is why that page also names laboratory equipment and auxiliary drives on precision machine tools.
YD, a stiff speed
Rotational speed stays nearly constant as the load changes. That is the curve named for drill presses and milling machines, and for the other stepped-speed machines on the series page.
Machine tools, mixers and conveyors are in the opening of the YD page, for fixed high and low speed. The FAQ adds marine and mining, including winches, drilling machines and lathes. Open the series page for the pairs, the example step, and the quote fields.
Open the YD page
YDT, the fan and pump curve
Same pairs, same 0.45–82 kW, same frames 80–280, same 220–690 V. The winding is variable torque. Output torque follows the square of the speed, which is the curve of a centrifugal fan or pump.
The series page states two figures. Cutting speed by half drops power to about one eighth. Against a single-speed motor on mechanical throttling, using the high speed at peak and the low speed off peak is about 30–50% lower energy. Contactors make that switch. Cooling towers, ventilation, HVAC and pump stations are the duties named there.
Large impellers are a high-inertia start. YDT specifies copper windings and a reinforced rotor so the start stays smooth on belts, pulleys and couplings.
Send both speeds
A multi-speed nameplate carries a power at every step. The pair decides which series page to open.
- YD or YDT
- Pole pair: 2/4, 4/6, 4/8, 2/4/6 or 4/6/8
- Kilowatts at each speed
- Voltage and frequency
- IEC frame
- Mounting: B3, B5, B35 or V1. The factory also builds B14, B34, V3 and V5.
Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected]
Before the quote
How many speeds do these motors have?
2 or 3. Two-speed pairs are 2/4, 4/6 and 4/8. Three-speed pairs are 2/4/6 and 4/6/8. YD and YDT both publish that list, at 0.45–82 kW and frames 80–280.
What separates YD from YDT?
YD holds a nearly constant speed as the load changes, for machine tools, mixers, conveyors, winches and lathes. YDT torque follows the square of speed for centrifugal fans and pumps. Halving speed drops power to about one eighth.
What if the speed has to move through a band, not two or three steps?
That duty is YVF2. It runs from a converter, constant torque from 5 Hz to 50 Hz and constant power from 50 Hz to 100 Hz, with an independent IC416 fan.