Cast-iron motor end shields stacked in the JWMotor plant

Plastics processing · Extruders on a VFD · Quote by machine duty

Plastic Machinery Motors

Our contact page lists plastic machinery among the uses of our motors, and our industries page puts plastics under manufacturing. We do not publish ratings for particular plastics machines, so this page sorts the drives by load type, names the series to start from, and lists what we need to confirm the motor.

S1Continuous duty, our manufacturing page
YVF2Our YVF2 page names extruders
YE3 · YE4IE3 and IE4 for fixed-speed drives
By quoteMachine ratings confirmed per drive

Plastics drives by load type

A plastics line has drives with very different loads. The series below are the ones our manufacturing, YVF2 and catalog pages name. The right column is what we confirm with you; we do not guess it.

Load typeSeries to start fromWhat our sources stateConfirmed with the quote
Screw drive on a frequency converterYVF2 inverter dutyOur YVF2 page: S1 continuous duty at low speed, suited to extruders; constant torque 5–50 Hz; separate cooling fanScrew torque across the speed range, gearbox ratio, converter make
Fixed-speed main drives and mixersYE3 or YE4Our manufacturing page: high starting torque for mixers and high-inertia loads, S1 dutyStarting load, inertia and starts per hour
Compressors and general processingYE3, YE4 or Y2Our industries page: continuous power for compressors, plastics and general processingkW, poles, mounting
Cooling fans and water pumps on the lineYDT for two or three speedsCatalog: YDT designed for fans and pumpsShaft power at each speed from the fan or pump maker
Geared auxiliary drivesRFKS on R, F, K or S reducersCatalog: automated lines, conveyors and packagingReducer family and size

Our manufacturing page also describes Class F/H insulation with VPI and a wide-voltage, 50/60 Hz design. The catalog tables are 380 V 50 Hz data; other voltages and 60 Hz are confirmed per order. See dual voltage motors and 60 Hz motors.

Technician checking the coupling guard between a blue motor and a gearbox on a plastics extrusion line base

The machine duty we ask for

Send these for each drive point on the machine.

01

Machine and drive point

Extruder, mixer, granulator, haul-off or auxiliary; which shaft the motor drives.

02

Speed and control

Fixed speed, or the speed range on a converter.

03

Torque

Torque at the lowest running speed and at start, from the machine maker.

04

Duty

Continuous or start-stop; starts per hour; overload you expect.

05

Heat around the motor

Air temperature near heaters and barrels.

06

Fit

Mounting, shaft drawing, voltage and frequency.

General-purpose motors for fixed-speed drives

Grey cast-iron housing, IP55, Class F, S1, per the catalog overview.

Three blue cast-iron motors of different frame sizes on a pallet, a technician measuring a shaft with a caliper

Fixed speed

YE3 · YE4 · Y2

YE3 (IE3): 0.18–630 kW, frames 80–400. YE4 (IE4): 0.55–630 kW, frames 80–400. Y2 (IE2): 0.09–900 kW, frames 63–450. Mounting B3, B5, B35 or V1, plus B14 and others on smaller frames.

IP55 · Class F · S1 · IC411 · 380 V 50 Hz catalog data · 1-year warranty

Speed control: YVF2 series · VFD motors. Non-standard fit: OEM electric motors · custom shaft motors.

How a plastics inquiry runs

Reply

We reply to every inquiry within 24 hours, per our service page.

Technical check

Engineers check the machine duty before the quote, so the rating is confirmed, not guessed.

Quote and sample

A quote in under 12 hours once the data is complete, and a single engineering sample for bulk and OEM orders.

From our service page. Every motor passes ten routine tests and ships with its own data sheet, per our quality page.

Send your machine duty

One line per drive point is enough to start.

  • Machine type and the drive point
  • Speed: fixed, or range on a converter
  • Shaft power, and torque at start and low speed
  • Duty: continuous or start-stop
  • Air temperature near the motor
  • Mounting, voltage, frequency and quantity
Send your machine duty

Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected] · 1-year warranty on all products

Plastic machinery motor questions

Which motor for an extruder screw?

If the screw runs on a frequency converter, start from YVF2: our YVF2 page names extruders and S1 duty at low speed, with a separate cooling fan. We confirm the size once you send the screw torque and speed range.

Do you publish torque ratings for extruders or injection machines?

No. We do not publish machine-specific torque or power ratings. The machine maker’s data decides the motor, and we confirm the model with the quote.

Which series for mixers and other fixed-speed drives?

YE3 or YE4. Our manufacturing page describes high starting torque for mixers and high-inertia loads. Y2 remains an option where first cost matters most.

Can the motor sit near heaters?

The catalog operating conditions give an ambient of up to +40 °C. If the air near the motor is hotter, tell us; Class H insulation is available on request.

Do you supply the gearbox?

We make the motor. RFKS motors fit R, F, K and S reducer families, and our flange motors mount directly on a gearbox input.

What warranty applies?

1 year on all products.