IEC 60072 · IEC 60034-30-1 · IEC 60034-5 · CE · CCC
IEC Motor Manufacturer
JWMotor designs and builds three-phase cage induction motors to IEC standards in its own factory. Mounting dimensions follow IEC 60072, efficiency classes follow IEC 60034-30-1, and the enclosure is IP55 to IEC 60034-5. This page sets out what each standard covers and which series we build to it.
What “IEC motor” means
An IEC motor is built to the motor standards of the International Electrotechnical Commission. For a buyer that comes down to a few things you can check on the data sheet and the nameplate.
Frame and mounting dimensions
IEC 60072 fixes shaft centre height, foot hole pattern, flange and shaft end for each frame number. A motor of the same frame from a different maker bolts to the same base. Our catalog states mounting dimensions to IEC 60072 and the Chinese GB/T 4772.1.
Efficiency class
IEC 60034-30-1 sets efficiency classes for single-speed, three-phase cage induction motors. Y2 is IE2 (high efficiency), YE3 is IE3 (premium) and YE4 is IE4 (super premium). The catalog states compliance with both GB 18613 and IEC 60034-30-1.
How efficiency is measured
Our catalog determines efficiency by the loss analysis method set out in GB/T 1032, with input and output power measured, not estimated from a nameplate.
Enclosure
IP55, meeting GB/T 4942.1 and IEC 60034-5. Our customization page lists IP55 and IP65 as standard options, with special sealing beyond that on request.
Rating, duty and cooling
Ratings to GB/T 755, continuous duty S1, cooling methods IC411 and IC416, thermal class 155 (F).
Mounting arrangement
Mounting codes to GB/T 997: B3, B5, B35 and V1 as the main positions, plus B14, B34, V3, V5 and others for smaller frames.
The standards in our catalog, and where they show
Every line below is printed in the overview of our 2025 catalog, except the vibration standard, which comes from our quality inspection.
| Standard | What it covers | On a JWMotor motor |
|---|---|---|
| IEC 60072 · GB/T 4772.1 | Mounting dimensions and frame numbers | B3, B5 and B35 dimension tables by frame: B3 and B35 frames 80–400, B5 frames 80–280 |
| IEC 60034-30-1 · GB 18613 | Efficiency classes of single-speed three-phase cage induction motors | Y2 IE2, YE3 IE3, YE4 IE4; RFKS motors for gear reducers are IE3 |
| GB/T 1032 | Test method for efficiency | Loss analysis from measured input and output power |
| IEC 60034-5 · GB/T 4942.1 | Degree of protection | IP55 enclosure |
| GB/T 755 | Rating and performance | Catalog performance tables, rated at 380 V 50 Hz |
| GB/T 997 | Mounting arrangement codes | B3, B5, B35, V1, B14, B34, V3, V5 and more, by frame range |
| ISO 10816-3 | Evaluation of machine vibration | Multi-axis vibration measured on every unit, balanced towards Zone A |
Frame range: the catalog overview gives centre heights H80 to H400 for the high-efficiency series; the Y2 tables run from frame 63 to 450. The Y2 product page lists frames 63–355; the catalog tables are the reference. Need the frame on your base matched? See IEC electric motors for same-frame replacement.

How the standard is held in production
A standard on paper means little without materials and tests behind it. These are the checks our quality and materials pages describe.
01
Frame data per size
Catalog dimension tables for B3, B5 and B35 by frame, confirmed on the drawing for each order.
02
Core steel
Baosteel 50W470 silicon steel, 0.5 mm, as standard. A 0.2 mm option for variable-frequency and high-speed use.
03
Copper and bearings
99.99% oxygen-free copper windings. SKF, NSK or C&U bearings, C3 clearance.
04
Insulation
Class F (155 °C) as standard with vacuum pressure impregnation. Class H on request.
05
Routine tests
Resistance, IR and PI, inter-turn, no-load, locked rotor, hi-pot at 2× rated + 1000 V, vibration and speed, on every motor.
06
One report each
Each motor ships with its own data sheet: resistance, hi-pot and vibration.
IEC series built to these standards
Three general-purpose series cover the IE2, IE3 and IE4 classes on IEC frames. Ranges are from the catalog performance tables.

General-purpose cast-iron motors
Y2 · YE3 · YE4
Y2 (IE2): 0.09–900 kW, frames 63–450. YE3 (IE3): 0.18–630 kW, frames 80–400. YE4 (IE4): 0.55–630 kW, frames 80–400. Two, four, six and eight poles, with ten-pole ratings in selected YE3 and YE4 sizes.
Grey cast iron · IEC 60072 mounting · IP55 · Class F · S1 · IC411
The same catalog also lists RFKS motors for gear reducers (IE3), YD and YDT pole-changing multi-speed motors, YVF2 variable-frequency motors and YEJ brake motors. Series pages: Y2 · YE3 · YE4 · RFKS · YD · YDT · YVF2 · YEJ
Who needs IEC credentials
Machine builders who export
Your machine has to meet the efficiency rule and frame system of the market it ships to. Tell us the country and we match the class.
Maintenance and replacement
A failed IEC motor is replaced by one of the same frame. Send the nameplate; see same-frame replacement.
Distributors and projects
One supplier for IE2, IE3 and IE4 on the same frame system, with custom mounting, voltage and shafts when the standard motor does not fit.
Choosing between classes? Read IE2, IE3 and IE4 compared.
Ask for IEC motor data
Tell us the market and the motor. We reply with the series, the class and the data sheet.
- Destination country and the efficiency rule you must meet
- kW, poles and frame, or a nameplate photo
- Mounting position (B3, B5, B35, V1 or other)
- Supply voltage and frequency
- Documents you need with the shipment
- Quantity
Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected] · 1-year warranty on all products
IEC motor questions
What is an IEC motor?
A motor built to IEC standards: frame and mounting dimensions to IEC 60072, efficiency class to IEC 60034-30-1, and enclosure protection to IEC 60034-5. Same-frame IEC motors from different makers share shaft height, foot pattern and flange.
Which efficiency classes do you build?
IE2 (Y2), IE3 (YE3) and IE4 (YE4), classified to IEC 60034-30-1. RFKS motors for gear reducers are listed as IE3.
Which certificates does JWMotor hold?
CE certification, and the national CCC certification since 2009. Ask for the documents your market needs when you inquire, and we confirm what we can supply.
How is motor efficiency determined?
By the loss analysis method in GB/T 1032, from measured input and output power, as stated in our catalog.
Do you supply 50 Hz and 60 Hz motors?
The catalog lists 50 Hz and 60 Hz as rated frequencies. Its performance tables are 50 Hz data, so 60 Hz ratings are confirmed with the quote. See 60 Hz motors.
Which class does my market require?
That depends on the country and the motor rating. Tell us where the motor will run. Our YE4 page covers EU Ecodesign Regulation (EU) 2019/1781 for 75–200 kW motors; for other markets we check with you before quoting.