Brake motor with a closed end cover and the shaft on the drive end

Power-off brake · 0.75–45 kW

YEJ series motors

Three-phase motors with a DC electromagnetic brake. When power drops, the spring locks the rotor. 0.75–45 kW, poles 2, 4, 6 and 8, frames 80–225, 220–690 V.

0.75–45 kWPower
2 · 4 · 6 · 8Poles
80–225IEC frame
0.15–0.45 sBraking time
Keyed shaft and foot of a brake motor

The spring locks the shaft

The brake is released while the motor is powered. On loss of power the spring engages and the rotor stops. Suspended loads stay put. Automated equipment stops short of an overshoot.

01

Fail-safe

A supply failure locks the shaft. The series page names lifted loads and conveyors that must not run on.

02

Rectifier in the box

The AC/DC rectifier sits in the terminal box. A standard AC supply is enough. No separate DC cabinet.

Time, release, air gap

03

Two published times

With the rectifier, power cut to standstill is about 0.2 seconds. Across frame sizes the series page gives 0.15 to 0.45 seconds.

04

Manual release

A lever releases the brake during an outage, maintenance or commissioning, so the shaft can be turned by hand.

05

Brake torque

Torque is set on the pressure springs. The series page asks for an air gap of 0.2 mm to 0.5 mm so the friction stays consistent.

06

Site conditions

Altitude up to 1,000 m. Above that altitude the series page calls for a power derating. Voltage tolerance is ±5%. Class H insulation is available.

Equipment named on the series page

Lifting

Vertical lifting, where the load has to stay where the power died.

Position

Automated assembly, stacker cranes, packaging and elevators.

Emergency stop

Warehousing and other stops where coasting is the problem the brake is there to end.

Send the stop

Tell us whether the brake is holding a lifted load or indexing a machine.

  • Kilowatts, poles and frame
  • Voltage and frequency
  • Vertical load or horizontal index
  • Braking time the machine needs
  • Mounting: B3, B5, B35 or V1. The factory also builds B14, B34, V3 and V5.
Request a quote

Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected]

Before the quote

How fast does it stop?

Typically 0.15 to 0.45 seconds, depending on frame size. With the rectifier module the series page also states about 0.2 seconds from power cut to standstill.

Can the shaft be turned in an outage?

Yes. The manual release handle frees the brake so the shaft can be rotated during an outage or during maintenance.

How is brake torque set?

On the pressure springs in the brake. Keep the air gap between 0.2 mm and 0.5 mm.