60 Hz Motors
If your plant runs on a 60 Hz grid, the motor has to be rated for it. Our catalog lists 50 Hz and 60 Hz as rated frequencies, and we match the electrical specification to your regional grid. Note that our published performance tables are 50 Hz data. Your 60 Hz ratings are confirmed with the quote.
What is published, and what we confirm for 60 Hz
This page shows no 60 Hz ratings, because the catalog does not contain any. Here is what it does contain.
| Item | In our catalog | For a 60 Hz order |
|---|---|---|
| Rated frequency | 50 Hz / 60 Hz listed in the standard technical characteristics | You state 60 Hz |
| kW, speed, current, efficiency | Tables at 50 Hz, mostly 380 V | 60 Hz values on the quoted datasheet |
| Rated voltage | 380, 400, 415, 660, 690 V; dual 220/380, 380/660, 400/690 V | Your grid voltage |
| Bearing design life | 20,000 h for 2-pole, 30,000 h for 4–10 pole, stated at 50 Hz | Ask for the 60 Hz figure |
| Mounting | B3, B5, B35, V1 to IEC 60072 | Choose as for any order |
| Test report | Each motor ships with its own data sheet | Ask what supply the test runs on |
Sources: catalog pages 4 and 5 and the series tables; rated voltage 220–690 V from the YE3, Y2 and YE4 product pages. Where the catalog and a web page differ, the catalog figure is used.

Why the frequency matters
A motor is designed for its supply. Read the 60 Hz values from its nameplate, not from a 50 Hz table.
01
Speed follows frequency
Synchronous speed = 120 × f ÷ poles. Same poles, different grid, different speed.
02
Ratings are set per frequency
Rated kW, current and torque belong to one supply. A 50 Hz table does not give 60 Hz values.
03
Grid, not converter
If 60 Hz is the output of a frequency converter, that is a VFD motor question.
04
Check the nameplate
Frequency, voltage and phases are on every nameplate. Our nameplate guide explains them.
Built for the grid it goes to
The motor is specified for the destination, not for the factory.

Voltage and frequency customization
Matched to your grid
Beyond standard configurations, we engineer electrical specifications to match your regional grid or industrial application. Our engineers check unusual voltages in technical verification, before quoting.
50 Hz / 60 Hz rated frequency · 380–690 V listed · IEC frames
Rated kW, speed, current and efficiency at 60 Hz are given per order. They are not published here.
Who asks for 60 Hz
Machines for export
Equipment built in one market and shipped to a 60 Hz market.
Replacements on 60 Hz sites
A failed motor replaced with one rated for the local supply.
OEM product lines
One design, built for each market’s grid. See OEM motors.
Also see dual voltage motors and customization.
Ask for a 60 Hz motor
Give us the grid first. Everything else follows from it.
- Supply: line voltage and 60 Hz
- kW and poles, or the output speed you need
- Nameplate photo of the motor it replaces
- Mounting: B3, B5, B35 or V1
- Efficiency class required in the destination market
- Quantity
Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected] · 1-year warranty on all products
60 Hz questions
Do you make 60 Hz motors?
Yes. Our catalog lists 50 Hz and 60 Hz as rated frequencies, and we customize the electrical specification to your regional grid.
Where are your 60 Hz ratings?
They are not in the catalog. All published performance tables are 50 Hz data. The 60 Hz values for your motor are given on the datasheet that comes with the quote.
Can I run a 50 Hz motor on a 60 Hz supply?
Do not assume so. Speed, current and torque all change with frequency and voltage. Send us the nameplate and your supply and we check.
Is a 60 Hz motor the same as a VFD motor?
No. A 60 Hz motor is rated for a fixed 60 Hz grid. A VFD motor runs across a frequency range on a converter. See VFD motors.
Which voltages can you build for 60 Hz?
The catalog lists 380, 400, 415, 660 and 690 V and dual 220/380, 380/660 and 400/690 V. It does not say which pairs with 60 Hz. Tell us your grid and we confirm.