Three-phase industrial motor on a steel base in a factory

Three-phase · IE2 to IE4

Industrial motors

Three-phase industrial motors. Y2, YE3 and YE4, IE2 to IE4. YD and YDT change poles, YVF2 runs on a VFD, YEJ has a brake.

Match the duty

The plant decides the line. Continuous running stays on Y2, YE3 or YE4. Fixed speed steps, a frequency converter, or a shaft that must stop, each has its own series.

Industrial motor bolted to a steel base

01 · On the supply

Y2, YE3, YE4

IE2 to IE4. Y2 is high starting torque on S1 duty, IEC frames 63–355, for pumps, fans, blowers, compressors and conveyors. YE3 has fewer losses than IE2, with 100% copper windings and IP55. YE4 takes another 15–20% off IE3 losses and typically runs 10°C to 15°C cooler. Check length and weight on YE4.

02 · Two or three speeds

YD and YDT change poles

YD switches the winding, for example from 4 poles to 8 poles, 1500 rpm and 750 rpm, with contactors. It is the line for 2 or 3 fixed speeds. YDT is the variable-torque version: output follows the square of the speed, for centrifugal fans and pumps.

03 · A frequency converter

YVF2, 5 Hz to 100 Hz

Inverter-duty, with an independent axial fan, IC416, so cooling holds at low speed. Constant torque from 5 Hz to 50 Hz. Constant power from 50 Hz to 100 Hz. Class H insulation. The non-drive end can take a rotary encoder.

04 · The shaft must stop

YEJ brake

A DC electromagnetic brake. Power off, the spring locks the rotor. Braking is typically 0.15 to 0.45 seconds. A manual release handle turns the shaft during an outage. The rectifier sits in the terminal box.

Quote the duty first

Name the line, or name the job: continuous, pole-change, VFD, or brake. Mounting and the regional grid are on the customization page.

Request a quote
  • Continuous, pole-change, VFD, or brake
  • kW, voltage, frequency
  • Poles, or the speed steps
  • Frame and mounting

Which line

What is an industrial motor here?

A three-phase motor for plant machinery. Y2, YE3 and YE4 cover continuous duty from IE2 to IE4. YD and YDT change poles for fixed speeds. YVF2 is built for a frequency converter. YEJ adds a power-off brake.

When is the line YD, YDT, or YVF2?

YD is for 2 or 3 fixed speeds, switched by contactors, including machine tools, winches, drilling machines and lathes. YDT matches centrifugal fans and pumps: on that page, halving speed drops power to about one eighth, and switching speeds can cut about 30% to 50% against a single-speed motor on a throttle. YVF2 covers 5 Hz to 100 Hz with IC416 cooling and Class H insulation, including S1 running at low speed on conveyors, extruders and automated lines. YE3 can also run from a frequency converter; cables over 50 m, or a voltage over 500 V, need a filter.

How does the YEJ brake behave when power drops?

The brake is power-off. Spring force locks the rotor, so a lifted load stays put. With the rectifier in the terminal box, braking is typically 0.15 to 0.45 seconds depending on frame size. A manual release handle frees the shaft during an outage or maintenance.