Inverter duty · 5–100 Hz
YVF2 series motors
Variable-frequency motors with an independent axial fan, IC416, and a Class H insulation system. 0.75–375 kW, frames 80–355, poles 2, 4, 6, 8 and 10, 220–690 V.

The fan has its own supply
A shaft-mounted fan slows when the motor slows. YVF2 uses a separately powered axial fan so the air stays at full capacity from crawl to top speed.
| Band | Output | Duty the series page names |
|---|---|---|
| 5–50 Hz | Constant torque | Conveyors and hoisting |
| 50–100 Hz | Constant power | Cutting and winding |
Built for the converter
01
IC416
The independent fan is the answer the series page gives for low-frequency running, where a shaft fan cannot move enough air.
02
Insulation
Class H, with vacuum pressure impregnation for the pulse voltage and harmonics of a converter, in line with NEMA MG1 Part 31.
03
Encoder
The non-drive end has a mounting face for a rotary encoder, for closed-loop speed or position with a vector converter.
04
Continuous low speed
S1 continuous duty at low speed is stated for conveyors, extruders and automated lines. The series page names ABB, Siemens and Schneider among the converters in this range.
Range
Power 0.75–375 kW and frames 80–355 are the figures on the series page, with rated voltage 220–690 V. Poles 2, 4, 6, 8 and 10 are the pole counts in the model list. Altitude up to 1,000 m, with a power derating above that. Voltage tolerance is ±5%.
Send the converter duty
The base frequency splits the two bands. Send where this motor sits.
- Kilowatts and pole count
- Supply voltage and base frequency
- Lowest and highest frequency
- Encoder, if the loop is closed
- Mounting: B3, B5, B35 or V1. The factory also builds B14, B34, V3 and V5.
Jiangxi Jiawang Special Motor · +86 199 0684 4761 · [email protected]
Before the quote
Why the separate fan?
YVF2 often runs at low speed. A shaft fan then moves too little air. The independent axial fan keeps the winding cool and protects the insulation.
What frequency range is published?
5 Hz to 50 Hz at constant torque, and 50 Hz to 100 Hz at constant power. The series page says that range works with converters such as ABB, Siemens and Schneider.
Can it run slowly all day?
Yes. Reinforced insulation and the separate cooling are specified for S1 continuous duty at low speed, including conveyors, extruders and automated lines.